TheUMOSTUspecificUinformationUaboutUtheUsizeUandUlocationUofUwindowsUwouldUbeUfou ndUinUaU-UcorrectUanswer-FloorUplan WhatUdirectionUdoesUheatUflow?U-UcorrectUanswer-HotUtoUcold WhatUareUbatterUboardsU-UcorrectUanswer- stakesUandUledgerUboardsUmarkingUbuildingUlines WhatUisUtheUMAXIMUMUdistanceUbetweenUaUventilatingUopeningUinUanUunder- floorUspaceUandUeachUcornerUofUtheUbuilding?U-UcorrectUanswer- 3 Ufeet WhatUisUNOTUrequiredUinUexteriorUnonbearingUwalls?U-UcorrectUanswer-Load- bearingUheaders AUlengthwiseUgrainUseparationUbetweenUorUthroughUtheUgrowthUringsUofUlumberUisUcalle dUaU-UcorrectUanswer-ShakeU(cU326) TheUabbreviationU"d"UinU"16d"UmeansU-UcorrectUanswer-Penny NotchesUmayUnotUbeUlocatedUinUtheU____________UofUaUjoistUspanU-UcorrectUanswer- MiddleU1/ HowUshouldUboardUandUbattenUbeUinstalled?U-UcorrectUanswer- 1 UinchUoverlapU10dUnails WhatUisUtheUmaximumUallowableUnotchUinUceilingUjoistsU-UcorrectUanswer- 1/6UtheUdepthUofUtheUmember HowUMUSTUraftersUbeUframedUtoUeachUotherU-UcorrectUanswer-GussetUplateU(R802.3)
WhatUisUusedUtoUpreventUbucklingUatUpointsUofUhighUstress?U-UcorrectUanswer- SquashUblocks PriorUtoUtheUinstallationUofUwoodUfloorUhowUlongUforUacclimation?U-UcorrectUanswer- 4 - 5 Udays WhereUdoUyouUstartUlayingUparquetUflooringU-UcorrectUanswer-Centerline WhatUisUtheUfirstUstepUinUcarpetUinstallation?U-UcorrectUanswer-TacklessUstrip WhatUtypeUofUnailUisUusedUinUfloorUinstallationU-UcorrectUanswer- 7dUorU8dUthreaded/CutUsteel WhatUshouldUbeUappliedUtoUcrevicesUinUwoodUflooring?U-UcorrectUanswer-Filling WhatUisUtheUbestUnailUforUhardwoodU-UcorrectUanswer-RingUshankUnail WhatUisUtheUmaximumUsizeUofUaUfloorUframeUopening?U-UcorrectUanswer- 5 UsqUftU(62)U(R310.2.1)/U 4 UftUheaderUjoistU(130)U(R502.10) WhenUinstallingUaUstringUofUwallUcabinets,UtheUcabinetsUshouldU-UcorrectUanswer- BeUattachedUtoUtheUadjacentUcabinetsUbeforeUtoUtheUwall WhatUisUtheUMINIMUMUheightUforUaUstairwayUhandrailU-UcorrectUanswer- 34 Uinches AUthirdUstairwayUstringerUshouldUbeUusedUwhenUtheUstairUwidthUexceedsU- UcorrectUanswer- 30 Uinches WhatUtypeUofUnailUareUbestUforUgeneralUconstruction?U-UcorrectUanswer-SmoothUshank WhatUisUtheUMAXIMUMUflameUspreadUindexUforUinsulationUmaterialsU-UcorrectUanswer- 25 U(R302.10.1) WhatUisUtheUMAXIMUMUdimensionUofUtheUventilationUcoveringsUforUunder-floorUspaceU- UcorrectUanswer-1/4UinchU(RU408.2) FlexibleUinsulationUplacedUinUfloorUjoistsUaboveUanUunheatedUcrawlUspaceUshouldU- UcorrectUanswer- BeUwellUsupportedUbetweenUjoists/usingUaUwireUmeshUorUrigidUboardU(cU 904 - 5) InUaUcrawlUspaceUhowUfarUfromUtheUfloorUjointsUdoUyouUneedUtoUplaceUvaporUretarderU- UcorrectUanswer-TopUSoil IceUdamUprotectionUneedsUtoUbeU_________UfromUtheUedgeUofUeavesU- UcorrectUanswer- 24 UinchesU(R905.1.2) WhereUtoUinstallUradiantUheatUbarrierUinUatticU-UcorrectUanswer-Rafters WhatUisUtheUmajorUadvantageUofUicyneneUoverUpolyurethaneUfoamU-UcorrectUanswer- CanUbeUpouredUinsteadUofUsprayed
WhenUinstallingUceilingUdrywall,UendUbuttUjointsUshouldU-UcorrectUanswer- NotUbeUbuttedUtightly/taped WhatUkindUofUdrywallUisUusedUthatUisUfireUresistantUtoUceilings?U-UcorrectUanswer- TypeUC/XU(cU917) InUwhichUdirectionUshouldUdrywallUbeUfastenedUtoUsteelUstuds?U-UcorrectUanswer- InUoneUdirectionUonly HowUfarUshouldUtheUscrewsUbeUplacedUonUaU3/8UceilingUdrywallUApplicaUadhesive?U- UcorrectUanswer- 16 WhereUdoesUoneUstartUwithUtheUinstallationUofUdrywall?U-UcorrectUanswer-Ceiling ScrewsUusedUtoUfastenUdrywallUMUSTUbeU-UcorrectUanswer-TypeUWUorUTypeUS MINIMUMUdistanceUbetweenUscrewsUonU1/2UinchUdrywallU-UcorrectUanswer- 12 UinchesU(cU924) WhenUinstallingUshoeUmoldingUonUaUbaseUboardUoverUhandUwoodUfloorU,UtheUshoeUmold UshouldUbe?U-UcorrectUanswer-NailedUtoUtheUbaseUboardUonlyU(cU982) InUdrywall,UwhatUisUJ-trimUusedUfor?U-UcorrectUanswer-toUprovideUaUfinishUedge WhatUtypeUofUcoatingUwillUnotUchalkUwhenUappliedUtoUexteriorUwallsU-UcorrectUanswer- Latex/Acrylic WhatUkindUofUsolventUcanUbeUusedUonUoilUbaseUpaint?U-UcorrectUanswer-Turpentine WhereUshouldUyouUstartUpaintingUaUroom?U-UcorrectUanswer-Ceilings WhatUcontrolsUtheUflowUofUpaintUinUanUairlessUsprayer?U-UcorrectUanswer-Orifice WhatUcausesUcrackingUorUallegatoring?U-UcorrectUanswer-NotUenoughUdrying- timeUinUbetweenUcoats WhatUisUtheUtypicalUexposureUofU 3 - tabUasphaltUshingles?U-UcorrectUanswer- 5 UinchesU(cU644) WhatUisUtheUMINIMUMUroofUslopeUREQUIREDUforUmodifiedUbitumenUroofing?U- UcorrectUanswer-1/4UinchUinU 12 U(R905.11) WhenUMUSTUaUsaddleUbeUinstalledUonUaUchimneyU-UcorrectUanswer- WhenUtheUchimneyUisUgreaterUthanU 30 UinchesUwide HighUwindUareaUhowUmanyUfastenersUperUshingleU-UcorrectUanswer- 6 Ufasteners WhatUmaterialUisUacceptableUforUvalleyUonUasphaltUshingleUroofUinstallationU- UcorrectUanswer-mineralUsurfacedUasphalt
WhatUisUtheUminimumUslopeUrequiredUofUasphaltUshingleUroof?U-UcorrectUanswer- 2 U1/2UinU 12 NailsUusedUtoUfastenUconcreteUroofingUtilesUmustUpenetrateUtheUdeckUaUMINIMUMUofUh owUmanyUinches?U-UcorrectUanswer-3/4Uinch WhatUisUtheUcorrectUsequenceUforUinstallingUaUbi-foldUdoorU-UcorrectUanswer- TopUtrack,UlowerUtrack,UinsertUbottomUpivot,UinsertUupperUpivot WhatUisUtheUMINIMUMUsquareUfootageUofUnetUclearUopeningUareaUforUanUegressUwindo wUinUaUsecondUfloorUsleepingUareaU-UcorrectUanswer-5.70UsquareUfeet WhichUwindowUtypeUconsistsUofUanUupperUandUaUlowerUsashUthatUslideUverticallyUinUtheU sideUjambs?U-UcorrectUanswer-DoubleUhung WhatUisUtheUmaximumUareaUforUaUwindowUglazingUpanelUinUaU 1 UhrUfireUratedUdoorUinstall ationUonUinteriorUwallU-UcorrectUanswer- 100 Usqft AUdoorUframeUconsistsUofUwhatUparts?U-UcorrectUanswer- 2 UsideUjambs,UOneUhead,U&UsurroundingUassembly WhatUisUtheUmaximumUthresholdUheightUforUR- 3 UegressUdoorU(nonUsliding)U- UcorrectUanswer-1/2Uinches DoorUcasingUshouldUbeU-UcorrectUanswer- NailedUtoUtrimmerUstudUandUthenUchalkedUtoUtheUwall WhatUisUtheUMINIMUMUwidthUofUaUmainUentranceUdoorUinUresidentialUconstruction?U- UcorrectUanswer- 3 Uft OnUaUfireUratedUexteriorUdoorUtheUhardwareUincludingUlatchingUforceUmayUnotUexceedU_ ______UIbsU-UcorrectUanswer- 15 Ulbs BuildingUcodesUrequiresUaUwindowUareaUnotUlessUthanU______UpercentUofUtotalUfloorUar ea?U-UcorrectUanswer- 8 TheUlowestUpartUofUtheUclearUopeningUofUaUwindowUshallUbeUaUminimumUofU- UcorrectUanswer- 24 UinchesUaboveUtheUfinishedUfloor HowUisUtheUhandUofUaUdoorUdetermined?U-UcorrectUanswer- ByUtheUlocationUofUtheUhingesUwhenUtheUdoorUisUviewedUfromUtheUinside. WhatUisUtheUMAXIMUMUdistanceUhorizontalUreinforcementUcanUbeUplacedUfromUtheUtop UofUaUmasonryUpartitionUwallU-UcorrectUanswer- 16 Uinches ForUmultiple- widthUmasonryUwhatUisUtheUMINIMUMUthicknessUofUgroutUbetweenUmasonryUunitsUandU reinforcementsU-UcorrectUanswer-1/4Uinch
HowUlongUmustUconcreteUcureUbeforeUinstallingUwoodUfloors?U-UcorrectUanswer- 60 Udays WhatUisUtheUdiameterUofU#5URebar?U-UcorrectUanswer-5/8Uinch WhatUisUtheUdiameterUofU#3Urebar?U-UcorrectUanswer-3/8Uinch WhatUisUusedUtoUremoveUairUpocketsUfromUplainUconcreteU-UcorrectUanswer-Vibration TimingUforUfloatingUandUtrowlingUisUcriticalUinUproducingU-UcorrectUanswer- AUsmoothUandUdurableUsurface WorkUsitesUmayUallowUmoreUwaterUtoUbeUaddedUtoUtheUconcreteUmixtureUifU- UcorrectUanswer-MaintainUtheUslump,UwithoutUexceedingUtheUallowUwaterU- UcementUratio WhatUisUtheUminimumUrequirementUforUtheUcompressiveUstrengthUofUconcreteUusedUinU aUgarageUfloorUinUaUsevereUexposureUareaU-UcorrectUanswer-3,500UPSI ActualUstandardUsizeUofUaUconcreteUblock?U-UcorrectUanswer- 7 U5/8UxU 7 U6/8UxU 13 U5/ WhatUisUtheUMINIMUMUbreakingUstrengthUrequiredUofUsafetyUbeltUlanyardsU- UcorrectUanswer-5,400Upounds WhatUisUtheUMINIMUMUclearanceUthatUcombustibleUinsulationUMUSTUotherUheat- producingUdevicesU-UcorrectUanswer- 1 Uinch TheUescapeUdeviceUforUaUtrenchUoverU 4 UfeetUdeepUMUSTUbeUwithinUaUMAXIMUMUofU- UcorrectUanswer- 25 UfeetUofUtheUworker WhatUisUtheUMINIMUMUilluminationUforUgeneralUconstructionsUareaUlightingU- UcorrectUanswer- 5 UfootUcandles EmployeeUbroughtUhisUownUtoolsUtoUwork,Uwho'sUresponsibleUforUtheUtoolsUsafetyUEmpl oyerUorUtheUemployeeU-UcorrectUanswer-Employer TheUfirstUstepUthatUneedsUtoUbeUtakenUpriorUtoUstartingUanyUexcavationUworkUisU- UcorrectUanswer-contractingUtheUlocalUutilityUcompanies ScaffoldsUMUSTUremainUaUMINIMUMUofUhowUmanyUfeetUfromUaU 50 - kVUpowerUlineU- UcorrectUanswer- 10 Ufeet GuardsUonUopenUsidedUwalkingUsurfacesUneedUtoUbeUlocatedUmoreUthan________mea suredUverticallyUtoUtheUfloorU-UcorrectUanswer- 6 Ufeet TheUtopUofUtheUladderUshallUextendUatUleastU_______UaboveUtheUedgeUofUtheUroofU- UcorrectUanswer- 3 UfeetUaboutUroof OSHAUrequiresUthatUguardrailsUbeUplacedUbetweenU__________UandU_________Uabo veUscaffoldUplanksU-UcorrectUanswer-38,
InUaUtrenchUwhatUisUtheUminimumUthatUaUsideUstepUfixedUladderUexteriorUplatform?U- UcorrectUanswer- 30 Uinches WhenUaUportableUladderUisUusedUforUaccessUtoUtheUupperUlandingUtheUsideUrailsUshallUb eU_________U-UcorrectUanswer- 3 Ufeet AnyUpersonUworkingUaboveU____UftUinUheightUshallUrequireUguardrailsUorUotherUfallUprev entionU-UcorrectUanswer- 6 WhatUisUtheUminimumUwidthUofUaUscaffoldUtoUrequireUguardUrailsUorUaUfallUarrestUsystemU