A comprehensive set of multiple-choice questions and answers related to the tcfp inspector's class, covering essential topics in fire and life safety. It includes questions on various aspects of fire safety regulations, codes, standards, and inspection procedures. Valuable for individuals preparing for the tcfp inspector's exam or seeking to enhance their knowledge of fire safety principles.
Typology: Exams
1 / 22
This page cannot be seen from the preview
Don't miss anything!
Which duty is not the responsibility of a level I Inspector? A) Handle citizen complaints related to fire and life safety. B) Perform plans reviews. C) Interpret and apply adopted codes and standards. D) Determine occupancy loads for single-use buildings. - ✔✔Perform plans reviews. Most of the consensus standards that relate to fire and life safety are developed by the following organizations except: ASTM International, National Fire Protection Assoc., American National Standards Institute, Underwriters Laboratories - ✔✔American National Standards Institute Regarding Commercial Kitchen Hood Systems, pipe penetrations of the exhaust hood require what? a. Minimum 18 inch clearance to combustible materials b. Printed manufacturer guidelines of spacing on the pipe itself c. Gas shut off valve and electrical shunt accessibility d. A liquid tight continuous external weld - ✔✔A liquid tight continuous external weld A independent, non-profit organization that tests products for their intended use and certifies them as safe describes: A) ASTM International B) American National Standards Institute C) Underwriters Laboratories Inc. D) Standards Council of Canada - ✔✔Underwriters Laboratories Inc.
Which is not one of the three general types of drawings used to show structure, facility, or site information? A. Plot plan B. Aerial view C. Floor plan D. Elevation view - ✔✔Aerial view Structural lumber has a moisture content of ___________% or less. 25% 19% 15% 12% - ✔✔19% Which of the following occupancies does not fall under state and local regulations? A). Day care B). Jail C). Post office D). Medical facility - ✔✔Post office The typical life cycle of a model code edition is ___ years. a. 5- 7 b. 2- 3 c. 7- 10 d. 3- 5 - ✔✔ 3 - 5 For Dry systems exceeding 500 gallons, there must be a quick opening device installed unless water is delivered to the system test connection within a specific time frame. What is this time frame? A. 30 seconds B. 60 seconds
B. Prescriptive Code C. Model Code D. Uniform Fire Code - ✔✔Model Code The demolition of a structure is included in what type/category of inspection? A. Change of occupancy B. Eminent hazard C. New Construction D. Response to a complaint - ✔✔New Construction An inspector assembles all of the necessary tools and equipment and PPE that may be needed for an inspection. Which of the following is NOT on the general list of commonly used items for fire inspections: A. Gloves B. Safety shoes or boots C. Thermal imagining camera D. Flashlight - ✔✔Thermal imagining camera The lightly constructed panel doors or glass doors used in general construction cannot act as barriers to high temperatures developed in a fire. Which of the following is NOT one of the three methods of classifying fire doors? A. Alphabetical letter designation B. Color coded designation C. Hourly fire-protection rating D. Combination of hour and letter - ✔✔Color coded designation The fire prevention division is managed by the _____________ , who typically holds the equivalent rank of assistant or deputy chief. A. City Marshal B. Fire Marshal C. Lead Inspector
D. Deputy Marshal - ✔✔Fire Marshal Because they are extremely unsafe and unreliable, _________________________ may not be used as any part of a means of egress in new construction. A. Internal fire escape stairs B. Outside fire slides C. External fire escape stairs D. None of the above - ✔✔External fire escape stairs Circle some of the duties of an inspector A) Handle citizen complaints related to fire and life safety B) Interpret and apply adopted codes and standards C) Interrogate citizens for not getting a permit D) A and B - ✔✔A and B What is an advantage of performance-based standards? A) Performance-based standards specify exactly what techniques and materials are required for compliance. B) Performance-based standards require significant technical expertise to implement. C) Performance-based standards allow for flexibility in meeting needs of AHJ, owners and insurance companies. D) Performance-based standards do not require frequent inspections or continued testing. - ✔✔Performance-based standards allow for flexibility in meeting needs of AHJ, owners and insurance companies.
. A ___ is a set of principles, protocols, or procedures that is developed by committees through a consensus process. A. code B. standard C. regulation D. legal document - ✔✔standard
B) Vertical or horizontal placement of the steel members C) Intensity of the exposing fire D) Load supported by the steel - ✔✔Vertical or horizontal placement of the steel members In regards to AFD Prevention Section Public Assembly Maintenance and Inspections, alarm systems are required in public assemblies with an occupant load of _______ or more. A. 200 B. 300 C. 400 D. 500 - ✔✔ 300 Listening makes up what percentage of time spent communicating? A) 42% B) 31% C) 15% D) 11% - ✔✔42% Official actions that can be taken to ensure code compliance are generally enacted in what order? A. Notification, Follow-up inspection, Prosecution, Sanction B. Follow-up inspection, Notification, Sanction, Prosecution C. Notification, Follow-up inspection, Sanction, Prosecution D. Prosecution, Sanction, Follow-up inspection, Notification - ✔✔Notification, Follow-up inspection, Sanction, Prosecution Three general types of drawings are used to show structure, facility, or site information. Which of the following are NOT one of those types? a. Floor Plan b. Earth View c. Plot Plan
d. Elevation Plan - ✔✔Earth View Which of the following is NOT a category that building roofs can be broadly classified into from a fire protection standpoint? a) flat b) truss c) pitched d) curved - ✔✔truss One method of persuasion is based on Monroe's Motivated Sequence Pattern developed by Alan Monroe in the 1930's. Which is NOT listed in the sequence? ATTENTION, NEED, ULTIMATUM, SATISFACTION - ✔✔ULTIMATUM _____ are commonly used in high-rise buildings and hospitals as a means of passing through a fire- barrier wall that separates two fire compartments in a structure. a) Horizontal exits b) Exit discharge c) Exit passageways d) Smokeproof enclosure - ✔✔Horizontal exits Which is not an hourly fire-protection rating given to fire doors? A. 4 hours B. 1 1/2 hours C. 1/2 hour D. 1/3 hour - ✔✔1/2 hour What are the two types of permits? A. Allowance & Granted B. C&D
d. beam - ✔✔truss From a fire-protection standpoint, building roofs can be broadly classified into three categories: A. domed, peaked, and slanted B. flat, pitched and curved C. rigid, non-rigid and semi-rigid D. fire resistant, non-combustible and combustible - ✔✔flat, pitched and curved _________ is a masonry structure that is built against a wall to provide additional support or reinforcement. A. Pilaster B. Buttress C. Corbelling D. Concrete Block - ✔✔Buttress A course of bricks laid across two wythes, with the ends of the bricks facing outward is known as a _______ course. A. soldier B. stretcher C. header D. brick faced - ✔✔header Generally in modern building Construction the are 5 types of doors used. Choose the one that does not fit in? A.) Swinging B.) Revolveing C.) Overhead D.) Folding - ✔✔Overhead
D. 8 x 8 - ✔✔8 x 8 An airport terminal is classified as what occupancy? A. Assembly B. Transit C. Business D. Industrial - ✔✔Assembly Some of the most important fire and life safety features built into a structure include? a. Exterior stairwells & fire doors b. Compartmentalization & fire resistance c. Structural components & occupancy classification d. Automatic sprinklers & fire detection systems - ✔✔Compartmentalization & fire resistance What type construction is non-combustible and limited combustible and provides the highest level of safety? A) Type I B) Type II C) Type III D) Type IV - ✔✔Type I An open parking garage would be classified as __ group, while a 9 Ft fence and private garages classify as __ group. A. S, U. B. B. U, S C. C. F, R D. D.. I, R2 - ✔✔A. S, U. Every structure is composed of the following building elements EXCEPT:
A) Structural Frame B) Floor Construction C) Roof Construction D) Door Peep Holes - ✔✔Door Peep Holes Which type of wall is erected to limit the maximum spread of fire: A) Party Wall B) Fire Wall C) Parapet Wall D) None of the above - ✔✔Parapet Wall What construction type is commonly know as "wood frame or "frame"? A. Type I B. Type II C. Type III D. Type V - ✔✔Type V Fire Escapes have been removed from the fire code a. for many decades b. since the 2012 Fire Code c. never, they are still permitted - ✔✔for many decades Regarding Institutional/health care facilities, which sentence is correct? a) In Institutional /health care facilities, either the local code or NFPA 101 will be applied but not both. b) In Institutional / health care facilities, more than one fire and life safety code may apply. c) In Institutional / health care facilities, NFPA 101 will always be used over the local code. d) In Institutional / health care facilities, because local codes are more stringent, NFPA 101 is irrelevant. - ✔✔In Institutional / health care facilities, more than one fire and life safety code may apply.
B) Emphasis should be placed upon the speed of the drill completion C) Emphasis should be placed upon orderly evacuation under proper discipline D) All of the above are true - ✔✔All of the above are true If panic hardware is required, the latch should release by applying a force of not more than __ lbs and set door in motion by applying force of no more than __ lbs. A. 10, 20 B. 5, 10 C. 10, 15 D. 15, 30 - ✔✔15, 30 In most cases, all of the codes require that there be at least ____ exists from any balcony, mezzanine, story, or portion thereof that has an occupant load of 500 persons or less. A. 1 B. 2 C. 3 D. 4 - ✔✔ 2 T or F Exit signs must be positioned so that at no point in the exit access is more than 150ft. - ✔✔False Hotel evacuation procedures should be posted________. A) in each room (usually on the back of the door) B) at all fire alarm pull stations C) next to exits D) all the above - ✔✔all the above _____ and _____ are the instruments that the inspector uses to create a safe environment for the residents and workers in the community. A. pen / paper
B. law / order C. standards / codes D. peanut butter / jelly - ✔✔standards / codes Which of the following is NOT a nonverbal communication: A) Eye Contact B) Facial Expression C) Personal Appearance D) All of the above are forms of nonverbal communication - ✔✔All of the above are forms of nonverbal communication Which of the following water supply systems is the most common? A. Gravity B. Direct C. Indirect D. Combination of gravity and direct pumping - ✔✔Combination of gravity and direct pumping There are five types of standpipe systems listed in NFPA14. They include all of the following EXCEPT: A) Automatic-wet B) Manual Automatic C) Manual Dry D) Manual Wet - ✔✔Manual Automatic Fire-flow tests may show a progressive reduction in water-flow capacity of the distribution system. Which of the following obstructions or conditions is NOT a reason for reduced water flow. A) Encrustations B) Malfunctioning valves C) Foreign matter other than deposits D) All are reasons for reduced flow - ✔✔All are reasons for reduced flow
B. Actual Width C. Natural Width D. Whole Width - ✔✔Gross Width Which of the following Groups does not include a complete (occupants and employees) evacuation during a fire drill: A. All of Group E B. Group R- 2 C. Group R-4 'assisted living ' D. All of Group F - ✔✔All of Group F In regards to stairs, landings must be provided so that no flights of stairs are greater than _____ feet high. a. 8 b. 10 c. 12 d. 14 - ✔✔ 12 Which of the following is not an example of an exit access? A) Unenclosed ramp or stairs B) Corridor leading to an exit opening C) Public way leading to an exit D) Occupied room or space - ✔✔Public way leading to an exit Which of the following statements about exits is not true? A. When more than one exit is required it would be meaningless to have everyone try to exit through two doors closely placed on one side of the room. B. When two exits are required, they are to be located not less than one-half the length of the overall diagonal dimension of the room or building area.
C. In spaces or structures where there is a requirement for more than two exits or exit access doors, at least two will meet the minimum separation requirements while the other exits are to be located in a manner that will allow them to be available if the primary exits become blocked or unavailable. D. None of the above - ✔✔None of the above In a Emergency evacuation plan you have evacuation routes, monitor duties, and Employee/occupant duties. In the employee/occupant duties section what does not apply. A.) Turn off all equipment B.) Close doors and windows C.) Ensure visitors are accounted for and evacuated from the building D.) Be the last one out - ✔✔Be the last one out If panic hardware is required, occupants should be able to cause the latch to release by applying a force of NOT more than _____ pound, and set the door in motion by applying a force of NOT more than _____ pounds. A. 7 and 20 B. 15 and 30 C. 10 and 30 D. 10 and 20 - ✔✔15 and 30 New ramps, complying with ADA requirements, have a minimum width of 44 inches and a slope of _________. A. 1: B. 1: C. 3: D. 2:15 - ✔✔1: While testing the HI/LOW Air pressure switch during Dry System trip test, the high air signal should be set at about what? A. 10 psi below the normal air pressure setting B. 10 psi above the normal air pressure setting