



















































Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
TCFP Driver Operator Masterclass. Top Rated Exam Study Guide Latest Updated 2025/2026 100% Correctly Answered.
Typology: Exams
1 / 59
This page cannot be seen from the preview
Don't miss anything!
C. Perform a sprinkler test D. Perform a hydrant test - ansanswer: A NFPA 1002: 10.2.1, 10.2.1(A) Page: 328
Page: 336
Page: 345
C. step in the apparatus's cab. D. move the pump's shift control switch into the "road" position. - ansanswer: A NFPA 1002: 4.3.7, 4.3.7(A), 5.2.4(1), 5.2.4(2), 5.2.4(3), 5.2.4(4), 5.2.4(A) Page: 308
D. Regulator - ansanswer: B NFPA 1002: 4.3.7, 4.3.7(A), 5.2.4(1), 5.2.4(2), 5.2.4(3), 5.2.4(4), 5.2.4(A) Page: 310
Page: 258
A. Logistics officer B. Safety officer C. Deputy operations section chief D. Staging area manager - ansanswer: D NFPA 1002: 4.3.1, 4.3.1(A), 4.3.6, 4.3.6(A) Page: 271
B. Minor traffic incidents C. Intermediate traffic incidents D. Major traffic incidents - ansanswer: D NFPA 1002: 4.3.1, 4.3.1(A), 4.3.6, 4.3.6(A) Page: 278
3 - A(n) _________________ is an apparatus designed to be more maneuverable than the pumper, but would require the same training as a pumper. - ansINITIAL ATTACK FIRE APPARATUS 3 - If a mobile water supply apparatus is equipped with a fire pump, then at least _____ of 2- 1/2" or larger supply hose must be available. - ans200 FT 3 - In the late 19th century, Scott-Uda designed a height extension ladder using eight extensions countered by weights and balances. These aerials were short lived because: - ansMANY PEOPLE DIED DUE TO THEIR COLLAPSE 3 - The five functions associated with a quint fire apparatus are: - ansPUMP, WATER TANK, FIRE HOSE STORAGE, AERIAL, AND GROUND LADDERS 3 - The job of a ___________ is to deliver foam immediately at the scene without requiring fire fighters to attach special containers or change nozzles. - ansMOBILE FOAM FIRE APPARATUS 3 - With the purchase of a new apparatus, it is important that training include: - ansALL ARE CORRECT (maintenance, equipment training, apparatus operation) 3 - Before a new apparatus is put into service, what must be completed? - ansTRAINING ON THE APPARATUS 4 - Approximately what percentage of the earth's surface is covered by water? - ans70-75% 4 - The amount of heat energy required to increase the temperature of a substance is known as it specific heat index. Water's specific heat index is: - ans 4 - When water is moving, it has a combination of potential energy and ________ energy. - ansKINETIC 4 - Principle 4 of fluid pressure that states, "The pressure of a liquid in an open vessel is proportional to the _____ of the vessel. - ansDEPTH 4 - One advantage of a wet-barrel hydrant is: - ansYOU CAN ADD HOSELINES WITHOUT SHUTTING OFF THE HYDRANT 4 - A fire hydrant that has a flow of 500-999 gpm at 20 psi would be considered what class of hydrant? - ansCLASS B 4 - The first part of a hydrant inspection is to: - ansCHECK THE EXTERIOR OF THE HYDRANT FOR SIGNS OF DAMAGE 4 - Flow testing should be done: - ansAT PEAK WATER FLOW TIMES 4 - Static water supplies are most commonly used in: - ansRURAL AREAS 4 - An alternative means of obtaining water in areas that are inaccessible to fire apparatus would be: - ansA PORTABLE PUMP 5 - All fire pumps are rated from a: - ansDRAFT 5 - According to NFPA standards, at 100 psi net pump pressure, a fire pump must deliver at least: - ans3000 GPM 5 - What type of pump is typically used as the priming pump for a centrifugal pump? - ansROTARY PUMP 5 - The centrifugal pump must be primed because: - ansIT CANNOT MOVE AIR