Information on energy efficient lighting, specifically the installation of compact fluorescent lamps (cfls) and light emitting diodes (led) exit signs. The benefits of cfls, the different types of fluorescent lamps, and the advantages of led exit signs. It also discusses the importance of energy savings in hotel design and the potential savings achievable through the use of energy efficient lighting.
What you will learn
Typology: Exams
1 / 7
This page cannot be seen from the preview
Don't miss anything!
Compact Fluorescent Lamps use a different, more advanced technology than incandescent light bulbs and come in a range of styles and sizes based on brand and purpose. They can replace regular, incandescent bulbs in almost any light fixture including globe lamps for the bathroom vanity, lamps for recessed lighting, dimming, and 3-way functionality lights. CFLs use about 2/3 less energy than standard incandescent bulbs, give the same amount of light, and can last 6 to 10 times longer. CFL prices range from $4 to $15 depending on the bulb, but you save about $25 to $30 per bulb on energy during the lifetime of the bulb.
Electric lighting is a major energy consumer. Enormous energy savings are possible using energy efficient equipment, effective controls, and careful design. Using less electric lighting reduces heat gain, thus saving air-conditioning energy and improving thermal comfort. Electric lighting design also strongly affects visual performance and visual comfort by aiming to maintain adequate and appropriate illumination while controlling reflection and glare.
Lighting is not just a high priority when considering hotel design; it is also a high- return, low-risk investment. By installing new lighting technologies, hotels can reduce the amount of electricity consumed and energy costs associated with lighting.
There are several types of energy efficient lighting and affordable lighting technology. The following are a few examples of energy-saving opportunities with efficient lighting.
When looking to purchase CFLs in place of incandescent bulbs, compare the light output , or Lumens , and not the watts. Watts refers to the amount of energy used, not the amount of light. In other words, if the incandescent bulb you wish to replace is 60 Watts, this is equal to 800 Lumens. To get the same amount of light in a CFL, you should look to find a CFL that provides 800 Lumens or more (equal to about a 13 watt fluorescent bulb). Use the table below to easily figure the conversions.
Incandescent Bulb (Watts)
Typical Lumens (Measure of Light Output)
40 > 450 60 > 75 > 100 > 150 >
Many lodging facilities may already use fluorescent lighting in their high traffic areas such as the lobby or office area. However, not all fluorescent lamps are energy efficient and cost effective. There are several types of fluorescent lamps that vary depending on the duration of their lamp life, energy efficiency, regulated power, and the quality of color it transmits.
There are a few styles worth noting; these models are simply labeled as “T-12”, “T-8”, or “T-5”. The names come from the size of their diameter per eighth inch. For example, a T-12 lamp is 12/8 inch in diameter (or 1 1/2 inch); a T-8 lamp is 8/8 inch in diameter (or 1 inch); a T-5 lamp is 5/8 inch in diameter. This is a simple way to identify the type of fluorescent lamps your facility is using.
The recommended style of fluorescent lighting is a T-8. T-8 lights are the most cost- effective. They usually cost about $0.99 a bulb and are 30% to 40% more efficient than standard T-12 fluorescent lamps, which have poor color rendition and cause eye strain. T- lamps provide more illumination, better color, and don't flicker (often exhibited by standard fluorescent fixtures). T-5 lamps are the most energy efficient and also tend to transmit the best color; however, they usually cost about $5.00 per bulb.
Each style of fluorescent lamp cannot function without a ballast. A ballast is an electrical device used in fluorescent lamps to regulate starting and operating characteristics of the lamp. Some ballasts are magnetic where as others are electronic. Electronic high frequency ballasts are now standard for most fluorescent lights. Due to the differences in wattage between the types of lights, if converting from a T-12 to a T-8 light, one must also change the type of ballast being used.
Note: It is important to discard all styles of fluorescent lamps appropriately. Because they contain a small amount of mercury, improper disposal could harm our soils or lakes. Fluorescent bulbs should be recycled , not thrown away.
Fluorescent lamps are categorized according to their diameter.
The development of light emitting diodes (LEDs) has allowed the replacement of exit sign lighting with a more energy efficient alternative. Multiple LEDs, properly configured, produce equivalent lighting and consume 95% less electricity than incandescent bulbs and 75% less than energy-efficient compact fluorescent lamps. A major benefit is the 20-year life cycle rating of LEDs; they virtually eliminate maintenance.
The key tag system uses a master switch at the entrance of each guest room, requiring the use of a room key-card to activate them. Using this technique, only occupied rooms consume energy because most electrical appliances are switched off when the key- card is removed (when the guest leaves the room). Along with lighting, the heating, air- conditioning, radio and television may also be connected to the master switch. This innovation has a potential savings of about $105.00 per room per year.
Many guests opt to have a light on while they sleep. By turning the bathroom light on and leaving the bathroom door cracked open, guests are able to find their way through an unknown room in the middle of the night. Those who are accompanied by children may often do the same to comfort their child. By offering a nightlight, the energy used to power a bathroom light during the nighttime can be avoided and guests will still be able to feel comfortable in unfamiliar territory.
One particular model uses six Light Emitting Diodes (LEDs) in the panel of a light switch to provide light for guests. LEDs are just tiny light bulbs that fit easily into an electrical circuit. They are different from ordinary incandescent bulbs because they don’t burn out or get really hot. They are often used in digital clocks or remote controls.
Of the three different styles of exit signs, incandescent signs are the least expensive, but are inefficient and use energy releasing heat instead of light. Fluorescent signs are also inexpensive and have an expected life of about 10,000 hours. LED exit signs are the most expensive, but are also the most efficient exit signs available. Their pay back time is usually about four years. The table on the following page offers an easy comparison of the three models of exit signs.
EXIT signs can be either green or red
Incandescent Fluorescent LED Input Power (watts) 40 11 2 Yearly energy (kWh) 350 96 18 Lamp life (years) 0.25-0.5 1-2 10+ Estimated energy cost/ year ($0.06/kWh)
$21.00 $5.75 $1.
Note: Not all LED exit signs are the same. Some are of lower quality and decrease their light output after a few years. Be sure to look for LED signs with semiconductor material that is made of aluminum, indium, gallium, and phosphor. Also, some LED signs have lights that are wired in a series circuit, meaning that when one LED light burns out, the whole sign loses its light. Look for LED exit signs that are wired in a parallel circuit.
High intensity discharge (HID) lighting is much more efficient and preferable to incandescent, quartz-halogen and most fluorescent light fixtures. HID types (from least to most efficient) include mercury vapor, metal halide and high pressure sodium. Mercury vapor is seldom used anymore. Both metal halide and high pressure sodium are excellent outdoor lighting systems. High pressure sodium has a pink-orange glow and is used when good color rendition isn’t critical. Metal halide, though less efficient, provides clean white light and good color rendition.
HID lighting is mostly utilized in floodlight, wall pack, canopy, post lantern and area fixtures outdoors. The best type for any application depends on the area being lit and mounting options.
Canopy Fixtures
Floodlight
Wall-Pack Fixture
Area Light
Post Lantern Post Globe
9. Resources for Energy Efficient Lighting