A comprehensive set of questions and answers for a bicsi practice test retake. It covers various topics related to telecommunications cabling, including fiber optics, copper cabling, and safety practices. Valuable for individuals preparing for bicsi certification exams or those seeking to enhance their knowledge in telecommunications infrastructure.

Typology: Exams

2024/2025

Available from 03/26/2025

Andreas-best
Andreas-best 🇬🇧

726 documents

1 / 10

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
1
BICSI PRACTICE TEST-RETAKE
QUESTIONS WITH CORRECT ANSWERS
"Which practice involves moving the customer to a temporary office space until their section of
the retrofit is completed and then moving them back to their recabled office space? - CORRECT
ANSWER Swing space phasing"
"Which of these testers would you clamp around a strand of fiber to check for the presence of
light? - CORRECT ANSWER Fiber strand identifier 11-11"
"A ______ provides a quick graphical representation of how the circuit is layed out? - CORRECT
ANSWER CLR 11-27"
"A ______ uses several pluggable modules to locate and Identify cables. - CORRECT ANSWER
Office locator kit"
"A _________ injects light (at a proper wavelength) and measures the results t the other end. -
CORRECT ANSWER Light source and power meter"
"A ________ detects the presence of light within a fiber strand - CORRECT ANSWER Fiber
strand identifier"
"A _______ uses a laser to identify fiber strands and find breaks in the fiber at the near end. -
CORRECT ANSWER Visual fault locator"
"A________ will leave the customer momentarily without communications - CORRECT
ANSWER Hot-cut 11-28"
"During a _______, cross-connects are relocated one pair after another until completed. -
CORRECT ANSWER Rolling cut"
"The nominal characteristic impedance of balanced twisted pair cable is _______ ohms at 100
MHz - CORRECT ANSWER 100"
"Pair 626 would be in the __________ Super Binder - CORRECT ANSWER Red"
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download BICSI Practice Test - Retake: Questions and Answers and more Exams Information and Communications Technology (ICT) in PDF only on Docsity!

BICSI PRACTICE TEST-RETAKE

QUESTIONS WITH CORRECT ANSWERS

"Which practice involves moving the customer to a temporary office space until their section of

the retrofit is completed and then moving them back to their recabled office space? - CORRECT

ANSWER Swing space phasing"

"Which of these testers would you clamp around a strand of fiber to check for the presence of

light? - CORRECT ANSWER Fiber strand identifier 11-11"

"A ______ provides a quick graphical representation of how the circuit is layed out? - CORRECT

ANSWER CLR 11-27"

"A ______ uses several pluggable modules to locate and Identify cables. - CORRECT ANSWER

Office locator kit"

"A _________ injects light (at a proper wavelength) and measures the results t the other end. -

CORRECT ANSWER Light source and power meter"

"A ________ detects the presence of light within a fiber strand - CORRECT ANSWER Fiber

strand identifier"

"A _______ uses a laser to identify fiber strands and find breaks in the fiber at the near end. -

CORRECT ANSWER Visual fault locator"

"A________ will leave the customer momentarily without communications - CORRECT

ANSWER Hot-cut 11-28"

"During a _______, cross-connects are relocated one pair after another until completed. -

CORRECT ANSWER Rolling cut"

"The nominal characteristic impedance of balanced twisted pair cable is _______ ohms at 100

MHz - CORRECT ANSWER 100"

"Pair 626 would be in the __________ Super Binder - CORRECT ANSWER Red"

"Series ______ is the preferred choice for longer runs - CORRECT ANSWER 11"

"The _________ connector/s have center pins (choose all that apply) - CORRECT ANSWER N

BNC"

"The range of human hearing is from _________ - CORRECT ANSWER 20 Hz- 20,000 Hz"

"An increase of _______ will result in a doubling or halving of the power. - CORRECT ANSWER

3 dB" "Increases or decreases of ________ for voltage will cause an increase or decrease of 10 times the

original value. - CORRECT ANSWER 6 dB"

"The code stands for "flush-or surface-mounted jack" - CORRECT ANSWER C"

"A "push to talk" intercom system would be an example of a ______ transmission method. -

CORRECT ANSWER half-duplex 1-1"

"__________ quantifies the bandwidth of a cabling system in a frequency range of interest. -

CORRECT ANSWER Megahertz"

"_________ refers to the amount of information that can be transported over the media. -

CORRECT ANSWER Megabit"

"A gauge change of ____ numbers approximately doubles or halves the conductors resistance -

CORRECT ANSWER 3"

"A gauge change of _______numbers approximately doubles or halves the conductors diameter

CORRECT ANSWER 6"

"______ is not recommended for new installations (what type of fiber) - CORRECT ANSWER

OM2"

"Modal bandwidth is described in terms of ________ - CORRECT ANSWER Megahertz per

kilometer"

"NEC ______ says that communication wires and cables shall be listed. - CORRECT ANSWER

800 A-38,39"

"Generic Telecommunications Cabling for Customer Premises (where to find) - CORRECT

ANSWER 568.0 A-38,39"

"Broadband coaxial cabling and components standards (where to find) - CORRECT ANSWER

568.4 A-38,39"

"The connection between the Horizontal cable and the backbone cable is called the ______ -

CORRECT ANSWER HC (FD)"

"A TE can serve a maximum of ________ - CORRECT ANSWER 3600 feet squared"

"The 2 different "types of backbone cabling are _______ and ______ - CORRECT ANSWER

Intrabuilding Interbuilding"

"A _______ connects a cable field to an active component. - CORRECT ANSWER

Interconnection"

"The maximum equipment cord length in the work area is _______ - CORRECT ANSWER 16.5'"

"The _______ topology is a linear configurations that places all of the network devices on one

length of cable. - CORRECT ANSWER Bus"

"In the ______ topology, the network switch is placed in the physical as well as logical center of

the network - CORRECT ANSWER Star"

"For all new installations, multipair backbone must meet the minimum performance of category

______ - CORRECT ANSWER 5e"

"A minimum of ________ telecommunications outlet/connectors is recommended per work

area. - CORRECT ANSWER 2"

"A _______ entrance is a means of providing out-of-sight service to a building without conduit. -

CORRECT ANSWER buried"

"A typical work area is ______ feet squared - CORRECT ANSWER 100"

"The firs of the 6 basic steps to safely assist others without endangering yourself is ________ -

CORRECT ANSWER Survey the scene"

"Stay at least _______ feet away from exposed energized electrical conductors, such as wires or

crane bus bars, operating at 300 - 50,000 volts - CORRECT ANSWER 10"

"________ milliamperes trigger ventricular fibrillation, which cause the heart to repeatedly relax

and violently clamp shut - CORRECT ANSWER 100 (3-22)"

"What does the "C" in "RACE" stand for? - CORRECT ANSWER Confine"

"Personnel should not lift a load in excess of ________ pounds per person - CORRECT

ANSWER 55"

"The horizontal distance from the base of the ladder to the supporting wall should be ________

the working length of the ladder - CORRECT ANSWER 1/4"

"Fall protection is required whenever a person is exposed to a fall hazard to another level of more

than ________ - CORRECT ANSWER 6 feet"

"Allow no more than_____ of conduit and bushing to extend into the room - CORRECT

ANSWER 3""

"Light, as measured within the TE, should be a minimum of _________ lux. - CORRECT

ANSWER 538 lux (or 50 foot candles)"

"If FMC must be used, limit the length to ________ - CORRECT ANSWER 20 feet"

"Toggle bolts should be installed __________ inches from the edges of the sheet of plywood -

CORRECT ANSWER 2"

"The recommended minimum separation distance from electric motors and transformers is

______ inches - CORRECT ANSWER 48"

"The maximum pull force for two- to- four strand optical fiber is ______lbf - CORRECT

ANSWER 50"

"Multipair copper cables require a minimum bend radius of _______ times their diameter -

CORRECT ANSWER 10"

"*________ is a property of an electromagnetic field built around a conductor that opposes any

changes in current flow in a circuit. - CORRECT ANSWER Inductance"

"_______ is a property of conductors that allows storage of electrical charges when potential

differences ( voltages) exist between the conductors. - CORRECT ANSWER Capacitance"

"The frequency of Category 8 cable is ______ - CORRECT ANSWER 2000 MHz"

"Series _____ is the preferred choice for longer coaxial runs - CORRECT ANSWER 11"

"You would look in ANSI/TIA - _______ if you needed information on the labeling standard -

CORRECT ANSWER 606"

"NEC ________ says that communication wires and cables shall be listed - CORRECT ANSWER

"Commercial Building Telecommunications Infrastructure Standard - CORRECT ANSWER

"The _______ provides space for an EF - CORRECT ANSWER Equipment room (ER)"

"The color field for the "Common Equipment" termination field is _________ - CORRECT

ANSWER Purple"

"________cabling is the portion of the telecommunications cabling system that connects the

work areas to the other telecommunications spaces - CORRECT ANSWER Horizontal"

"For all new installations, multipair backbone must meet the minimum performance of category

______ cable - CORRECT ANSWER 5e"

"There are ______ types of cross-connections. - CORRECT ANSWER 3"

"One ______ can serve a single department, multiple groups, or all other users within a building.

CORRECT ANSWER LAN"

"Each port on a _______ is a separate communications channel representing a different collision

domain. - CORRECT ANSWER Switch"

"A ______ is a device that manages one or more resources shared by workstation users and

administrators on a network - CORRECT ANSWER Server"

“The 2 main considerations concerning the existing cabling are? - CORRECT ANSWER

Grandfathered system Abandoned cable 11-25" "The type of cutover where cross-connects are relocated one pair after another until completed is

called a - CORRECT ANSWER rolling cut 11-28"

"*_________ is a property of an electromagnetic field built around a conductor that opposes any

changes in current flow in a circuit. - CORRECT ANSWER Inductance"

"____________ is a property of conductors that allows storage of electrical charges when

potential differences (voltages) exist between the conductors. - CORRECT ANSWER

Capacitance" "*In AC circuits, the total opposition to current flow is called _________, which is measured in

ohms. - CORRECT ANSWER Impedance"

"The way in which others perceive an employee can be divided into 3 distinct areas: body

language, Tone of voice and choice of words. Which of the 3 makes the biggest impression? -

CORRECT ANSWER Body language - 55%"

"What type of fibers typically support wavelengths of 850 nm and 1300nm - CORRECT

ANSWER OM

OM

OM3"

"The ______ serves as the dedicated extension of the buildings ac grounding electrode system for

the telecommunications infrastructure. - CORRECT ANSWER PBB (8-11, 8-16)"

"The recommended maximum value for the bonding resistance between the grounding electrode

and the busbar in the EF or TR is _______ milliohms - CORRECT ANSWER 100"

"Cabinets and racks should be set in place and leveled throughout the lineup. Leveling foot adjustments or shimming of any anchoring point should not exceed _______ inch(es) unless

specified by the project engineer. - CORRECT ANSWER 0.5"

"Where optical fibers will be used, consider placing three innerducts ( two _____ and one ____)

inside each 4" conduit designated for this purpose to ensure physical cable protection -

CORRECT ANSWER 1.5"

"The minimum bend radius for coaxial cable (semi-rigid) is _________ time the cable diameter -

CORRECT ANSWER 20"

"The minimum bend radius for intra-building optical fiber cable during installation is _______

times the cable diameter. - CORRECT ANSWER 15"